CAT: BFP/VCAR
C3V0427
Ø14.27
Ø15.87
2
1
3
99
2.5
8.1
39
39.5
46
24
3/4" - 16UNF
36
Ø 20
Q (l/min)
P(bar)
0
1
2
3
4
5
6
0
24
6810
12 14
16 18 20
B
A
Q (l/min)
P(bar)
0
25
50
75
175
100
200
125
225
150
250
0
24
6810
12 14
16 18 20
A
B
IE/C3V0427/002/2012 SHEET: 1/1
9
C3V 04 27 1D D S * ** 2
1
3
2
SOLENOID VALVES 3-WAY/2-POSITION
HYDRAULIC FEATURES
PRESSURE DROPS
HYDRAULIC SYMBOL
Max. working pressure 250 bar
Max. Flow 20 l/min
Max. excitation frequency 2 Hz
Duty cycle 100% ED
Hydraulic fluid DIN 51524 Mineral oils
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamin. level class with filter ISO 4406:1999 - class 19/17/14
Type of protection (in relation to the
connector used)
IP 65
Weight 0.30 kg
Cartridge tightening torque 25 ÷ 30 Nm
Coil ring nut tightening torque 4.5 Nm
Cavity (3/4 - 16 UNF) CD018003 (See section 15)
LIMIT OF USE
ORDERING CODE
D = Seat
1D = Hydraulic schema
27 = 27W (A09)
04 = 3/4 - 16 UNF
2 = Serial No.
Series
Size
Schema
Coil
Seat type
Voltage
Variants
(1) Only voltages 12 VDC - 24 VDC
(2) With rectifier: 115 VAC/50Hz - 120 VAC/60Hz
(3) With rectifier: 230 VAC/50Hz - 240 VAC/60Hz
(4) Performance are guaranteed only using valves completed with BFP coil
C3V = Solenoid valve 3 way / 2 positions
The tests were carried out with the 27W
solenoids at operating temperature, with
a supply voltage 10% below nominal
value and with a 40°C fluid temperature.
The fluid used is a mineral oil with viscosity of
46 mm²‘/s at 40°C.
Flow
Pressure
drops
Limit
of use
2 → 1 A A
2 → 3 B A
3 → 2 B B
Curve
SOLENOID VALVES - 3-4 WAY
S = Without emergency
Version
Connector to be ordered separately, see sect. 18
Coils technical data, see sect. 17
Connector to be ordered separately, see sect. 18
DC 27W (A09)
L = 12 VDC
M = 24 VDC
N = 48 VDC
P = 110 VDC
Z = 102 VDC RAC (2)
X = 205 VDC RAC (3)
W = Without coil (4)
The electric valve is a 3-way 2-position directional electrically controlled
valve.
Slight leakage is tolerated for this type of valve.
The valves work with DC coils whereas RAC coils with a connector with incor-
porated rectifier must be used for AC applications.
The sleeve is in phosphate steel. The plunger is in tempered and ground steel.
00012027
Spare seals kit
00 = No variants
FL = Coil with flying leads (250 mm) (1)
LD =
Coil with flying leads (130 mm) and integrated diode
(1)
AJ = AMP Junior coil (1)
CX = Deutsch coil and integrated diode (1)
Page: 81